BRAND | Integra Metering AG (formerly Aquametro) |
Product | VZF 25 FL 180/JIS 16K 94118 |
Internal code | IMP4819883 |
Please send us your request per e-mail, so we can send you our offer with competitive prices and delivery time for Integra Metering AG (formerly Aquametro) - VZF 25 FL 180/JIS 16K 94118 number or any other model you need. We can offer competitive price, and delivery time with wide products distribution network in Croatia Industrial products Market.
WE SELL ONLY NEW AND ORIGINAL PRODUCTS!
[M-Bus Mini-Master USB - M-Bus level converter Mobile M-Bus level converter with USB interface, - Integrated M-BUS power supply (32 M bus load units) - Two LED to indicate data traffic in sending and receive direction - Protection against overcurrent and short circuit on the M-Bus - supply from the USB interface, no external Supply needed]
VSR 32 1 1 / 4'' OR Klinger Sil; Fittings DN 32 Fittings R 1 1/4 " Union nuts G 1 1/2 " without boundary (brass) with seals
VSR 40 1 1/2 '' OR Klinger Sil; Fittings DN 40 Fittings R 1 1/2 " Union nuts G 2 " without boundary (brass) with seals
some glands
Ring piston Durchflussm. DOMINO rotary piston meters - stainless steel casing, flanges DIN 2501 - measuring chamber stainless steel - piston ring graphite - seals PTFE / Variseal
tellers
DOMINO® ARD Construction Group - Reguliergetriebe - pulser for high temperatures NAMUR / DIN 19234 - Roller 6 digits, rotatable. - lock ring with lid
Nominal flow: Qn = 6; Nominal diameter: DN 32; Reporting: 1 liter of 1impuls
Nominal flow: Qn = 10; Nominal diameter: DN 40; Reporting: 1 liter of 1impuls water meter
Nominal flow: Qn = 6; Nominal diameter: DN 32; Reporting: 1 liter of 1impuls
Nominal flow: Qn = 6; Nominal diameter: DN 32; Reporting: 1 liter of 1impuls
Nominal flow: Qn = 10; Nominal diameter: DN 40; Reporting: 1 liter of 1impuls
Nominal flow: Qn = 10; Nominal diameter: DN 40; Reporting: 1 liter of 1impuls
Nominal flow: Qn = 6; Nominal diameter: DN 32; Reporting: 1 liter of 1impuls
Nominal flow: Qn = 6; Nominal diameter: DN 32; Reporting: 1 liter of 1impuls
Nominal flow: Qn = 6; Nominal diameter: DN 32; Reporting: 1 liter of 1impuls
(CONTOIL ® fuel oil meters Reed pulser Pulse value 12.5 ml Nominal diameter: 8 mm With female thread for Kupferrohrverschr. 1/4 " Nominal pressure: PN 25 Maximum permissible temperature: 60 ° C Mounting position: horizontal / vertical Largest flow Qmax. 200 l / h In continuous operation: 135 l / h Error of measurement: 4-200 l / h ± 1% of measured value Pulse value: 0.0125 l)
VZO 15 ... 40 with thread, PN 16
oil meter Nominal width: DN 20 mm With flanges DN 20 according to: DIN 2501 Overall length: 165 mm Nominal pressure: PN 25 bar Maximum allowable temperature: 130 ° C Mounting position: horizontal / vertical Largest flow Qmax. 1,500 l / h In continuous operation Qn:. 1,000 l / h Minimum flow Qmin. 30 l / h Error of measurement: 30 - 1,500 l / h ± 1% of measured value Repeatability equal / better than: 0.2% Total amount on roller: 10 million liters Smallest readable Quantity: 0.1 l
oil meter
[AMBUS IS M-Bus pulse collector 1 pulse input 2 conductors M-bus interface 2 conductors with energy supply from AMBUS ZS or Net]
PMG 32-RH1 6.0_260_1 G1 / 4 multi-jet vane hot water meter in glanded Thread connection: G 1 1/2 " Nominal size: DN 32 Mounting length: 260 mm Mounting position: horizontal Temperature: max. 130 ° C Nominal pressure: PN 16 Minimum flow qi: 0,075 m³ / h Continuous flow qp: 6 m³ / h Maximum flow qs: 12 m³ / h Kvs-value: 12.7 m³ / h Pressure loss at qp: 0,22 bar Pulse value: 1 liter / pulse Environmental class C according to EN 1434 no inlet: 0 x DN 32 no outlet flow: 0 x DN 32 Approval MI-004
Size: DN 32 with thread 1 1/2 "(for screw 1 1/4") Nominal pressure: PN 16 bar length: 150 mm Mounting position: vertical falling temperature max .: 130 ° C Maximum flow qs: 6.3 m3 / h Nominal flow qp: 5 m3 / h minimum flow qi: 0.1 m3 / h pulse value: 1 l Smallest readable amount: 0.1 l registrable: 99,999 m3 measuring principle: multi-jet impeller, dry running With CE marking
PMGS 32-RH1 5.0_150_1 G1 / 4 multi-jet vane hot water meter in glanded Thread connection: G 1 1/2 " Nominal size: DN 32 Mounting length: 150 mm Mounting position: vertical ascending Riser counter Temperature: max. 130 ° C Nominal pressure: PN 16 Minimum flow qi: 0.1 m³ / h Continuous flow qp: 5 m³ / h Maximum flow qs: 6,3 m³ / h Kvs-value: 13.6 m³ / h Pressure loss at qp: 0,14 bar Pulse value: 1 liter / pulse Environmental class C according to EN 1434 no inlet: 0 x DN 32 no outlet flow: 0 x DN 32 Approval MI-004
MeiStream RUBIN cold water meters Nominal size: DN 50 Flange connection: EN 1092-1 Nominal pressure: PN 16 bar Overall length: 200 mm Mounting position: horizontal / vertical Protection: IP 68 Temperature max .: 50 ° C Overload flow Q4: 90 m3 / h Permanent flow rate Q3: 50 m3 / h Transition flow rate Q2: 0.4 m3 / h Minimum flow rate Q1: 0.15 m3 / h Smallest readable amount: 0.5 l Registration capacity: 1 million m3 Measuring principle: Woltman turbine Measuring range delivery designation: R 100
PMW-basic 32 10._260_1 G1 / 4; Multi-jet vane hot water meter in glanded Thread connection: G 1 1/2 " Nominal size: DN 32 Mounting length: 260 mm Mounting position: horizontal Temperature max. 90 ° C. Nominal pressure: PN 16 Minimum flow Q1: 0.1 m³ / h Permanent flow Q3: 10 m³ / h Maximum flow Q4: 12.5 m³ / h Kvs-value: 12.7 m³ / h Pressure loss in Q3: 600 mbar Measuring range: R 100 Inlet section: 0 x DN 32 Outlet flow: 0 x DN 32 Degree of protection: IP 66 Approval MI-001
PMWF-basic 32 10._150_1 G1 / 4 multi-jet vane hot water meter in glanded Thread connection: G 1 1/2 " Nominal size: DN 32 Mounting length: 150 mm Mounting position: vertical falling Pipe meter Temperature max. 90 ° C. Nominal pressure: PN 16 Minimum flow Q1: 0.1 m³ / h Permanent flow Q3: 10 m³ / h Maximum flow Q4: 12.5 m³ / h Kvs-value: 10.3 m³ / h Pressure loss in Q3: 900 mbar Measuring range: R 100 Inlet section: 0 x DN 32 Outlet flow: 0 x DN 32 Degree of protection: IP 66 Approval MI-001
PMW-basic 16._300_1 40 1/2 ''; Multi-jet vane hot water meter in glanded Thread connection: G 1 " Nominal size: DN 40 Mounting length: 300 mm Mounting position: horizontal Temperature max. 90 ° C. Nominal pressure: PN 16 Minimum flow Q1: 0.16 m³ / h Permanent flow Q3: 16 m³ / h Maximum flow Q4: 20 m³ / h Kvs-value: 25.6 m³ / h Pressure loss in Q3: 400 mbar Measuring range: R 100 Inlet section: 0 x DN 40 Outlet flow: 0 x DN 40 Degree of protection: IP 66 Approval MI-001
PMWS-basic 16._200_1 40 1/2 ''; Multi-jet vane hot water meter in glanded Connection thread: G 2 " Nominal size: DN 40 Mounting length: 200 mm Mounting position: vertical ascending Riser counter Temperature max. 90 ° C. Nominal pressure: PN 16 Minimum flow Q1: 0,16m³ / h Permanent flow Q3: 16 m³ / h Maximum flow Q4: 20 m³ / h Kvs-value: 20.8 m³ / h Pressure loss in Q3: 600 mbar Measuring range: R 100 Inlet section: 0 x DN 40 Outlet flow: 0 x DN 40 Degree of protection: IP 66 Approval MI-001
PMWF-basic 16._200_1 40 1/2 ''; Multi-jet vane hot water meter in glanded Connection thread: G 2 " Nominal size: DN 40 Mounting length: 200 mm Mounting position: vertical falling Pipe meter Temperature max. 90 ° C. Nominal pressure: PN 16 Minimum flow Q1: 0,16m³ / h Permanent flow Q3: 16 m³ / h Maximum flow Q4: 20 m³ / h Kvs-value: 22.2 m³ / h Pressure loss in Q3: 600 mbar Measuring range: R 100 Inlet section: 0 x DN 40 Outlet flow: 0 x DN 40 Degree of protection: IP 66 Approval MI-001