QP-3300  - Ascon Croatia  Sales

BRAND Ascon
Product QP-3300
Description universal controller series QP
Internal code IMP547105
Weight 1
Technical specification - Supply voltage: 100... 240 Vac, 50/60 Hz - serial interface: RS485 (JBus, ModBus, protocol) - Continuous output Y6: without - Input: configurable to * Pt100 * thermocouples (L, J, T, K, S, R, B, N, W) or * Continuous signals linearly or with square root conversion 0 (4)... 20 mA, 0... (50) 200 mV, 0... 1 V, 1... 5 V, 0... 5 V, or 0... 10 V - Output (hardware): * Main output Y1: relay, logic or continuous * up to 4 alarm relays (depending on configuration) - Y2... Y5 * Auxiliary output Y2: alarm relay * Auxiliary output Y3: alarm relay * Auxiliary output Y4: alarm relay (not for 3-point control) * Auxiliary output Y5: alarm relay (only if Y1 steady or logic) - Control behavior (configurable) on/off hysteresis, heating or cooling characteristics, Heating/cooling characteristics or 3-point step (engine control, OPEN-NEUTRAL-CLOSE) - dimensions: 96 x 96 mm DIN, depth 150 mm - Degree of protection: front IP54 (IP65 optional) - Display: setpoint, actual value and manipulated variable - Default: * PID fuzzy algorithm with self-optimization and setpoint ramps * three configurable digital inputs (3 sped. Set points, keypad lock, auto/man, int./ext. setpoint) * 24 Vdc voltage output for ext. transmitter * Control variable limitation * Handheld device options: - Continuous output Y6 for actual value, set value or manipulated variable - Configuration tool for PC

Please Contact Us to Order to offer competitive prices and delivery time for Ascon - QP-3300 universal controller series QP number, also you may ask some other model number is well. We can offer competitive price, and delivery time with wide products distribution network in Croatia Industrial products Market. 

WE SELL ONLY NEW AND ORIGINAL PRODUCTS!

Our company is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.

More products of Ascon

M4-5107-0000

Transmitterversorgung und Analog-Ausgang

M4-3107-0000

temperature controller

M4-3107-0200

thermostat

M5-3100-1200

(Controller / program controller series M5-3100-1200 A-No .: G-No .: Front: 48 x 48 mm Supply voltage: 100 ... 240 V, 50/60 Hz Logic inputs: 2 Auxiliary input: no Output OP1: relay (2A / 250V contact) Output OP2: relay (2A / 250V contact) Output OP3: relay (2A / 250V contact) Serial interface: no Interface protocol: no Actual value OP4: no Front color: dark gray Setpoint program: up to 16 segments can be configured as follows: Input: PT100; Thermocouple J, L, T, K, S, R, T; 0 ... 50 mV DC 0 (1) .... 5 V DC; 0 .... 10V DC, 0 (4) ... 20 mA Control: ON / OFF, PID, heating or cooling, Heating / cooling, 3 pt step Options: ext. Setpoint, current transformer Entrance, continuous control output, or serial interface)

M5-3101-0200

.Regler Series M5-3101-0200 (unkonfiguriert)

M5-3151-0200

.regler

M9 MA

HEAT INDICATOR

M9-3151-0000 price valid only in 6-pack

user manual in English only (Gewicht 250g)

M9-3151-0000/AHL OEM/Kundenspezifisch

regulator Type: M9-3151-0000 / AHL Case dimensions: 48 x 48 mm Power supply: 100 ... 240V AC with 2 relay outputs Serial interface RS485 + IPOT

MS30/099

Policy

MS-30/30 ABA(replaced by MS-32/.9999)

Configuration 99/99 Power supply 100/240V

MS-30/9999/ADM

(Digital Controls MS (series unconfigured) - Power supply voltage: 100 ... 240V, 50/60 Hz - Serial interface: 2-wire TTY, ASCII optinoal - Dimensions: 48 x 48 mm DIN, depth 110 mm - Weight approx 200 g - input (configurable): * Pt100 * Thermocouple (L, J, K, S) * Standard signal 0 (4) ... 20 mA or 0 ... 1 (10) V Exit: * Main output Y1: relay or logic * Auxiliary output Y2: Alarm relay - PID control with self-optimization and setpoint ramp - heating or cooling characteristic with alarm output or Heating / cooling characteristic without alarm output configurable - Simultaneous display of set and actual values - control output configurable as relays or logic signal - ramp function - Power limitation - scalable inputs for standard signals - configuration via front keys - Voltage output for external 24 V - Transmitter - Parameter lock - Front protection: IP 54, with transparent cover IP 65 (optional) - Customs number: 9032/1020)

MS-32/9999

Digital controller

MS-50/9999

Digitalregler der Serie MS

PT100

Temp. resistence detector ZTR-23M/1P.

PT100-ZTR-23M1/1P/002200

Thermoresistance

Other Category Brands